75GPD Reverse Osmosis Membrane



75GPD Reverse Osmosis Membrane
This is a description of the Vontron ULP1812-75 Reverse Osmosis Membrane, which is a 75GPD (gallons per day) membrane used for desalination and purification of water. It is suitable for various applications such as household water purifiers, hospital and laboratory water purifying devices, and food and pharmaceutical production. The membrane has a stable rejection rate of 97.5% and a minimum rejec... more details
Key Features:
  • 75GPD (gallons per day) capacity: This membrane is able to produce up to 75 gallons of purified water per day, making it suitable for household and commercial use.
  • Reverse Osmosis: The membrane uses a reverse osmosis process to remove impurities, contaminants, and dissolved solids from water.
  • High rejection rate: The membrane has a stable rejection rate of 97.5%, meaning it effectively removes a high percentage of impurities from water.


R493.35 from SEAL Water Tech

price history Price history

BP = Best Price   HP = Highest Price

Current Price: R493.35

loading...
Features
Brand Unbranded
Manufacturer Vontron
Model Number RO-M75GPDV
Description
This is a description of the Vontron ULP1812-75 Reverse Osmosis Membrane, which is a 75GPD (gallons per day) membrane used for desalination and purification of water. It is suitable for various applications such as household water purifiers, hospital and laboratory water purifying devices, and food and pharmaceutical production. The membrane has a stable rejection rate of 97.5% and a minimum rejection rate of 96.0%. It has been tested and treated before leaving the factory and should be stored and used according to specific guidelines to ensure optimal performance.

Vontron ULP1812-75 Reverse Osmosis Membrane.This membrane is rated at 75 Gallons per day (280 litres per day).
  • Fits in standard 1.8" x 12" residential RO membrane housings.
VONTRON Residential Membrane ElementsBrief IntroductionThe 1812-sized and 2012-sized residential membrane elements are mainly applicable to various small-sized systems, such as household water purifier and other water purifying devices in hospital and laboratory.
Being suitable for the desalting treatment of those water sources with salt concentration lower than 2000 ppm, such as surface water, underground water, tap water and municipal water, etc., ULP series are mainly applicable to numerous applications of various sizes, such as pure water, boiler water replenishment, foodstuff processing, and pharmaceutical production, etc.Specifications and Major PropertiesActive Membrane Areaft(m):3.5(0.32)
Average Permeated Flow: 75 GPD
Stable Rejection Rate:97.5%
Minimum Rejection Rate: 96.0%

Testing Conditions:

Testing Pressure60 psi (0.41Mpa)
Temperature of Testing Solution25C
Concentration of Testing Solution (NaCl) 250ppm
pH Value of Testing Solution 7.5
Recovery Rate of Single Membrane Element 15%
Extreme Operation Conditions:Max. Working Pressure: 300psi(2.07Mpa)
Max. Feedwater Temperature: 45C
Max. Feedwater SDI: 5
Free Chlorine Concentration of Feedwater pH Range of Feedwater during Chemical Cleaning: 2~12
Max. Pressure Drop of Single Membrane Element: 10psi(0.07Mpa)

Important Information

1. Any specific application must be limited within the extreme operating conditions. We strongly recommend you to refer to the latest edition of technology manual and design guide prepared by Vontron Technology Co., Ltd., or consult experts proficient in membrane technology. In case the customer fails to follow the operating conditions as specified in this manual, Vontron technology Co., Ltd. will assume no liability for all results.

2. The permeate flow listed in the table is the average value. The permeate flow of single membrane element is within a tolerance not exceeding 20% of the nominal value.

3. All wet-type membrane elements have been strictly tested before leaving the factory, and have been treated with the solution of 1.0% sodium hydrogen sulfite (an antifreeze solution of 10% propanediol required in winter) for storage purpose, then sealed with plastic bag in vacuum, and further packed in carton boxes. In order to prevent the breeding of microbes during short-time storage, transportation and system standby, we recommend you to soak the membrane elements with protective solution (prepared with RO filtered water) containing 1.0% sodium hydrogen sulfite (foodstuff-purpose).

4. Discard the RO-filtered water produced during the first one hour after system start-up.

5. During storage time and run time, it is strictly prohibited to dose any chemical medicament that may be harmful.