Pulse Oximeter CMS50DL1



Pulse Oximeter CMS50DL1
The pulse oximeter CMS50DL1 is a device that measures the oxygen saturation in the blood. It has a range of 0% to 100%, a pulse rate measuring range of 30 bpm to 250 bpm, and a measurement accuracy of 2% in stage of 70%-100% Sp02, and meaningless when stage being smaller than 70%. It also has a resolution of 1% for Sp02 and 1 bpm for Pulse Rate. The oximeter is resistant to surrounding light and h... more details
Key Features:
  • Measures oxygen saturation in the blood
  • Range of 0% to 100%
  • Pulse rate measuring range of 30 bpm to 250 bpm


R561.90 from Cleansafe Labs

price history Price history

BP = Best Price   HP = Highest Price

Current Price: R561.90

loading...
Features
Brand Unbranded
Manufacturer Unbranded
Model Number POX50DL1
Description
The pulse oximeter CMS50DL1 is a device that measures the oxygen saturation in the blood. It has a range of 0% to 100%, a pulse rate measuring range of 30 bpm to 250 bpm, and a measurement accuracy of 2% in stage of 70%-100% Sp02, and meaningless when stage being smaller than 70%. It also has a resolution of 1% for Sp02 and 1 bpm for Pulse Rate. The oximeter is resistant to surrounding light and has a deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom of less than 1%. It also has a performance in weak filling condition of Sp02 and pulse rate being shown correctly when pulse-filling ratio is 0.4%. The oximeter consumes less than 25 mA of power and requires 2 x1.5V AAA alkaline battery (or using the rechargeable battery instead).

Pulse Oximeter CMS50DL1
Basically function:
Display Sp02,PR saturation value;
Pulse rate and Puise rate Bargraph;
Battery-low indicator;
The Oximeter can be powered off automatic ;
Technical specifications
Sp02 Measuring Range:
0% -100%;
Pulse Rate Measuring Range:
30 bpm - 250 bpm;
Measurement Accuracy:
2% in stage of 70%-100%Sp02, and meaningless when stage being smaller than 70%. 2 bpm or2% (select larger) for Pulse Rate.
Resolution:
1% for Sp02 and 1 bpm for Pulse Rate.
Resistance to surrounding light:
The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than 1%. Measurement Performance in Weak Filling Condition: Sp02 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. Sp02 error is 4%, pulse rate error is 2 bpm or 2% (select larger). Power Consumption:
Smaller than 25 mA.
Power Requirements:
2 x1.5V AAA alkaline battery (or using the rechargeable battery instead), adaptable range: 2.6V-3.6V.