| Brand | Unbranded |
| Manufacturer | Unbranded |
| Model Number | SIM400MP |
Simulator MS400 Patient Multiparameter ECG/Arrhythmia ECG Conventional: All leads have the same voltage with the II-lead as the reference Amplitude: 0.5,1.0,1.5 and 2.0mV The accuracy of Amplitude: 2% ECG Rate: 15,20,25,30,40,60,80,100,120,140,160,180,200,220,240,260,280,300,320,340 and 350 BPM ECG artifacts: 50 or 60 Hz, muscle, baseline drift and breathing The elevation of the ST segment: -0.8 mV to +0.8 mV, the step is 0.1 mV The default: 80 BPM,1mV Arrhythmia Atrial: Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm, Supraventricular Tachycardia Ventricular: Vent Fib (coarse), Vent Fib (fine), Premature Ventricular Contraction (PVC) 6/min, PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, Asystole Premature Beat: Atrial Premature Atrial Contraction (PAC), Nodal PNC, Left Ventricular Focus PVC1, Early Left Ventricular Focus PVC1, Right Ventricular Focus PVC1, Early Right Ventricular Focus PVC1, R on T Left Ventricular Focus, R on T Right Ventricular Focus, Multifocal PVC Conduction Defects: First Degree Heart Block, Second Degree Heart Block, Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch Block ECG Performance Testing ECG amplitude0.5,1.0,1.5 and 2.0mV The accuracy of Amplitude: 2% Pulse: 30 and 60 BPM, the width of pulse wave is 60 ms Square: 0.125 and 2.0 Hz Triangle: 2.0 and 2.5 Hz Sine: .0.5, 5, 10, 40, 50, 60 and 100 Hz ECG Rate:15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, 320, 340 and 350 BPM The accuracy of ECG Rate: 1% Respiration Respiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIIN Respiration Impedance: 0.2, 0.5, 1.0 and 3.0 Baseline Impedance:500,1000,1500 and 2000 Apnea: 12 s, 22 s, 32 s ECG simulator with adjustable heart rate/12-lead output 33 kinds of Arrhythmia waveforms Pacemaker Two IBP channels Variety of respiratory impedance,apnea pauses (0 BrPM) of 12, 22 and 32 seconds.
Standard ECG calibration Export square,triangle and sine with adjustable frequency IBP The default: 00/00mmHg Dynamic IBP Channel 1: Artery 120/80mmHg Radial 120/80mmHg Left Ventricle 120/00mmHg Right Ventricle 25/00mmHg Channel 2: Artery 120/80mmHg Radial 120/80mmHg Left Ventricle 120/00mmHg Right Atrium 15/10mmHg Right Ventricle 25/00mmHg Pulmonary Artery 25/10mmHg Left Atrium 14/4mmHg Static-Pressure Levels Channel 1: 0, 80, 160, 240, 320 and 400mmHg Channel 2: 0, 50, 100, 150, 200 and 250mmHg
Loading similar products...
Stay informed about the best deals and price drops. Choose which notifications you'd like to receive from PriceCheck.
Free easy-to-follow course for anyone in South Africa who wants to learn how to start a digital business.