Geyserwise Max Thermal Controller Unit



Geyserwise Max Thermal Controller Unit
The Geyserwise Max Thermal Controller Unit is a popular thermal controlling selection in South Africa's market. It is used as a geyser timer, solar system timer, and differential control on pumped solar system. The Geyserwise has a clear display of water temperature, time, day, heating mode and malfunction conditions. The Geyserwise has an electronic thermostat with mechanical thermal cut-out at 9... more details
Key Features:
  • Thermal controller unit
  • Timer
  • Solar system timer

price history Price history

BP = Best Price   HP = Highest Price

Current Price: R1 242.00

loading...
Features
Brand Unbranded
Manufacturer Unbranded
Description
The Geyserwise Max Thermal Controller Unit is a popular thermal controlling selection in South Africa's market. It is used as a geyser timer, solar system timer, and differential control on pumped solar system. The Geyserwise has a clear display of water temperature, time, day, heating mode and malfunction conditions. The Geyserwise has an electronic thermostat with mechanical thermal cut-out at 90C. The Geyserwise is also used as a timer on a thermosiphon solar system. The Geyserwise has a temperature display range of 0 - 99C (-5 when below -5C EA when above 99C). The Geyserwise has a high temperature warning above 84C. The Geyserwise has a temperature setting range of 30 - 65C (heating water electrically). The Geyserwise has a heat failure when increase at a rate of less than 4C per hour. The Geyserwise has a temperature probe range for collector of -30 to + 260C. The Geyserwise has a temperature tolerance of 2%. The Geyserwise has a switching differential of 6C. The Geyserwise has a 2nd temperature probe for solar. The Ge

Geyserwise Description
Geyserwise products are a popular thermal controlling selection in South Africa's market.
Use as a geyser timer
Clear display of water temperature, time, day, heating mode and malfunction conditions.
Auto or manual heating.
Easy temperature setting to your requirements (30 - 65C) factory default is 55C.
Four different temperature settings.
Daily programmable timer with four time settings.
Error conditions alert by warning code E1 to E7.
Electronic thermostat with mechanical thermal cut-out at 90C.
Use as timer on a thermosiphon solar system
Clear display of water temperature, time, day, heating mode and malfunction conditions on solar system and geyser.
Auto or manual heating.
Easy temperature setting to your requirements (30 - 65C) factory default is 55C.
Four different temperature settings.
Daily programmable timer with four time settings.
Error conditions alert by warning code E1 to E7.
Electronic thermostat with mechanical thermal cut-out at 90C. Please note the cut-out temperature for solar systems expected to reach temperatures above this temperature.
Use as timer and differential control on pumped solar system
Clear display of water temperature, time, day, heating mode and malfunction conditions on solar system and geyser.
Auto or manual heating.
Easy temperature setting to your requirements (30 - 65C) factory default is 55C.
Four different temperature settings.
Daily programmable timer with four time settings.
Error conditions alert by warning code E1 to E9.
Electronic thermostat with mechanical thermal cut-out at 90C. Please note the cut-out temperature for systems expected to reach temperatures above this temperature.
Differential controller 12V and 220V systems.
Technical Parameters
Operating voltage 230VAC / 50HZ.
Main Relay contact rating 30AMP (Max 4KW).
Secondary relays pump and solenoid 5Amp.
Operating voltage range 160V 250V AC.
Earth leakage protection at 25MA action time = 0,1 second.
Temperature display range 0 - 99C (-5 when below -5C EA when above 99C).
High temperature warning above 84C.
Temperature setting ranges 30 - 65C (heating water electrically).
Heat failure when increase at a rate of less than 4C per hour.
Temperature probe range for collector is -30 to + 260C.
Electronic thermostat with mechanical thermal cut-out at 90C.
Dry heat detection empty cylinder.
A temperature tolerance 2%.
Temperature differential setting 1C.
Switching differential 6C.
2nd temperature probe for solar.
Solar differential 7C.
The temperature probe range for geyser is -30 to + 130C.
Collector antifreeze protection at 5C
Frequently asked questions:
How does the timer / controller work?
There are no offers currently available for this product. The last offer was seen on 30/01/2024 from SolarAdvice for R1 242.00
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.