Geyserwise Delta T Digital Controller



Geyserwise Delta T Digital Controller
The Geyserwise Delta T Digital Controller is a timer and differential control for pumped solar systems. It has a clear display of water temperature, time, day, heating mode and malfunction conditions on the solar system and geyser. The controller has auto or manual heating, easy temperature setting to your requirements (30 – 65°C) factory default is 55°C, four different temperature s... more details
Key Features:
  • Digital controller for pumped solar systems
  • Clear display of water temperature, time, day, heating mode and malfunction conditions
  • Auto or manual heating

price history Price history

BP = Best Price   HP = Highest Price

Current Price: R1 121.25

loading...
Features
Brand Unbranded
Manufacturer Geyserwise
Description
The Geyserwise Delta T Digital Controller is a timer and differential control for pumped solar systems. It has a clear display of water temperature, time, day, heating mode and malfunction conditions on the solar system and geyser. The controller has auto or manual heating, easy temperature setting to your requirements (30 – 65°C) factory default is 55°C, four different temperature settings, daily programmable timer with four time settings, error conditions alert by warning code E2 to E5 and E7 to E9, electronic thermostat with mechanical thermal cut-out at 90°C, and dry heat detection. The controller has a switching differential of 6°C and 2nd temperature probe for solar. The controller has a solar differential setting range of 7°C – 15°C, temperature probe failure detection for both collector and tank, temperature probe range for geyser is -30 to + 130°C, and temperature probe range for collector is -30 to + 260°C.

Use as timer and differential control on pumped solar system:


  • Clear display of water temperature, time, day, heating mode and malfunction conditions on solar system and geyser

  • Auto or manual heating

  • Easy temperature setting to your requirements (30 – 65°C) factory default is 55°C

  • Four different temperature settings

  • Daily programmable timer with four time settings

  • Error conditions alert by warning code E2 to E5 and E7 to E9

  • Electronic thermostat with mechanical thermal cut-out at 90°C

  • Please note the cut-out temperature for systems expected to reach temperatures above this temperature

  • Differential controller 220V pumped solar systems


Technical parameters


  • Operating voltage 230VAC / 50HZ

  • Main relay contact rating 20AMP (Max 4KW)

  • Secondary relays pump 5Amp

  • Operating voltage range 160V – 250V AC

  • Temperature display range 0 – 200°C (“-5” when below -5°C “EA” )

  • High temperature warning above 85°C

  • Temperature setting ranges 30 – 65°C (heating water electrically)

  • Heat failure – when increase at a rate of less than 4°C per hour

  • Electronic thermostat with mechanical thermal cutout at 90°C

  • Dry heat detection – empty cylinder

  • Temperature tolerance ± 2%. Temperature differential setting 1°C

  • Switching differential 6°C

  • 2nd temperature probe for solar

  • Solar differential setting range 7°C – 15°C

  • Temperature probe failure detection for both collector and tank

  • Temperature probe range for geyser is -30 to + 130°C

  • Temperature probe range for collector is -30 to + 260°C

  • Isolate L when in off state

  • Collector antifreeze protection setting range 0 – 10°C

There are no offers currently available for this product. The last offer was seen on 30/01/2024 from SolarAdvice for R1 121.25