Godin Ecoval 13 Kw Freestanding Fireplace Black



Godin Ecoval 13 Kw Freestanding Fireplace Black
GENERAL SPECIFICATIONS
CHIMNEY AND ITS CONNECTION
Before installation, ensure that the chimney is in good condition and that the duct ensures a satisfactory draught.
Depression must be 1.5mm water gauge, at least. i.e. 1.5mm WG (0.06WG)
The chimney should be well insulated
 It must be airtight and its cross section area must be const... more details

price history Price history

BP = Best Price   HP = Highest Price

Current Price: R27 495.00

loading...
Features
Manufacturer Godin
Model Number 362105
Description
GENERAL SPECIFICATIONS
CHIMNEY AND ITS CONNECTION
Before installation, ensure that the chimney is in good condition and that the duct ensures a satisfactory draught.
Depression must be 1.5mm water gauge, at least. i.e. 1.5mm WG (0.06WG)
The chimney should be well insulated
 It must be airtight and its cross section area must be constant.
The minimum area of cross section must be no less than 2.5dm2 (39sq inches) which corresponds to 180mm. On the other hand, an excessively large area of cross section produces too great volume, which is difficult to heat and is one of the principle causes of poor draught.
A comparison cannot be made with previous units results, where the air supply is different.
An efficient chimney must be built with materials, which have poor heat conductive capacity
The chimney must only vent one fireplace
It must suitably emerge into free air at least 0.40m above the rooftop or any other obstacle situated within distance of 8 meters from the chimney
Any chimney deviated must be very open angled
The draught must range between 1.5mm WG and 2mm WG when burning normally and must drop at 0.5mm WG roughly when burning slowly. If the draught is too high, a damper should be fitted. If the draught is insufficient, check if the characteristics of the chimney comply with those prescribed in this paragraph
If the cross-section of the fireplace is too large, the volume to be heated is too big and the draught wont be able to reach satisfactory levels. In such cases, the chimney shall require internal piping with tubes adapted to wood fires. The pipes diameter should in no case be inferior to 180mm. Never obstruct the air louver installed in the door
Never obstruct the air louver installed in the door
It is recommended that a well sealed sweeping/cleaning trap is fitted approximately 50cm below the axis of the smoke duct
Never reduce the diameter of the extraction pipe designed for the appliance. The majority of problems experienced during the operation of the units are related to an adjustment in the specified chimney conduit. We cannot emphasize this enough
The origin of the chimney must be located in the same room as the appliance
The connection between the stoves pipe and the chimney must be perfectly airtight
Note: It is essential to check that the room in which the appliance is installed is well ventilated to provide adequate air supply